Basit öğe kaydını göster

dc.contributor.authorApak, Resat
dc.contributor.authorTekdemir, Yasemin
dc.contributor.authorTurker, Lemi
dc.contributor.authorErcag, Erol
dc.contributor.authorCan, Ziya
dc.contributor.authorUzer, Aysem
dc.date.accessioned2021-03-03T16:51:24Z
dc.date.available2021-03-03T16:51:24Z
dc.identifier.citationCan Z., Uzer A., Tekdemir Y., Ercag E., Turker L., Apak R., "Spectrophotometric and chromatographic determination of insensitive energetic materials: HNS and NTO, in the presence of sensitive nitro-explosives", TALANTA, cilt.90, ss.69-76, 2012
dc.identifier.issn0039-9140
dc.identifier.othervv_1032021
dc.identifier.otherav_46939211-cd7f-46d9-ae21-a672b96ccef2
dc.identifier.urihttp://hdl.handle.net/20.500.12627/51035
dc.identifier.urihttps://doi.org/10.1016/j.talanta.2011.12.077
dc.description.abstractAs there are no molecular spectroscopic determination methods for the most widely used insensitive energetic materials, 2,2',4,4',6,6'-hexanitrostilbene (HNS) and 3-nitro-1,2,4-triazole-5-one (NTO), in the presence of sensitive nitro-explosives, two novel spectrophotometric methods were developed. For HNS and TNT mixtures, both analytes react with dicyclohexylamine (DCHA) forming different colored charge-transfer complexes, which can be resolved by derivative spectroscopy. The spectrophotometric method for NTO measures the 416-nm absorbance of its yellow-colored Na+NTO- salt formed with NaOH. TNT, if present, is pre-extracted into IBMK as its Meisenheimer anion forming an ion-pair with the cationic surfactant cetyl pyridinium (CP+) in alkaline medium, whereas the unextracted NTO is determined in the aqueous phase. The molar absorptivity (epsilon. Lmol(-1) cm(-1)) and limit of quantification (LOQ mg L-1) are as follows: for HNS, epsilon = 2.75 x 10(4) and LOQ = 0.48 (in admixture with TNT); for NTO, epsilon = 6.83 x 10(3) and LOQ = 0.73. These methods were not affected from nitramines and nitrate esters in synthetic mixtures or composite explosives. The developed methods were statistically validated against HPLC, and the existing chromatographic method was modified so as to enable NTO determination in the presence of TNT. These simple, low-cost, and versatile methods can be used in criminology, remediation/monitoring of contaminated sites, and kinetic stability modeling of munitions containing desensitized energetic materials. (C) 2012 Elsevier B.V. All rights reserved.
dc.language.isoeng
dc.subjectKimya
dc.subjectTemel Bilimler
dc.subjectKİMYA, ANALİTİK
dc.subjectAnalitik Kimya
dc.subjectTemel Bilimler (SCI)
dc.titleSpectrophotometric and chromatographic determination of insensitive energetic materials: HNS and NTO, in the presence of sensitive nitro-explosives
dc.typeMakale
dc.relation.journalTALANTA
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume90
dc.identifier.startpage69
dc.identifier.endpage76
dc.contributor.firstauthorID23445


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster