Biomechanical comparison of three different plate configurations for comminuted clavicle midshaft fracture fixation
Date
2017Author
YILDIZ, FATİH
Batar, Suat
Bozdag, Ergun
Bilsel, Kerem
Kuduz, Hacer
UZER, GÖKÇER
Metadata
Show full item recordAbstract
Background: The aim of this study was to compare the fixation rigidity of anterior, anterosuperior, and superior plates in the treatment of comminuted midshaft clavicle fractures.
Collections