Show simple item record

dc.contributor.authorUlgen, Yekta
dc.contributor.authorSEZDİ, MANA
dc.date.accessioned2021-03-03T17:22:22Z
dc.date.available2021-03-03T17:22:22Z
dc.date.issued2007
dc.identifier.citationUlgen Y., SEZDİ M., "Physiological quality assessment of stored whole blood by means of electrical measurements", MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, cilt.45, sa.7, ss.653-660, 2007
dc.identifier.issn0140-0118
dc.identifier.othervv_1032021
dc.identifier.otherav_495b3972-c7a0-46f3-8478-0cd43706375d
dc.identifier.urihttp://hdl.handle.net/20.500.12627/52776
dc.identifier.urihttps://doi.org/10.1007/s11517-007-0206-x
dc.description.abstractThe physiological parameters of blood such as extracellular Na+, K+, Cl-, pH, 2,3-DPG and ATP and the complex electrical impedance were measured using whole blood samples from 31 male donors (21 donors form the training set and ten donors were used for testing), on the 0th, 10th and 21st day of blood bank storage. During storage, while the extracellular fluid resistance (R-e) and the intracellular fluid resistance (R-i) decreased progressively with time, the effective cell membrane capacitance (C-m) has increased. Blood bank storage resulted in a rise in K+ and a fall in Na+, Cl-, pH, 2,3-DPG and ATP. Accordingly, all electrical parameters correlated with Na+, K+, Cl-, pH and ATP, at varying levels. By applying the multi-regression analysis, it was demonstrated that R-i, R-e and especially C-m were appropriate for the assessment of Na+, K+, Cl-, pH and ATP until the 21st day of storage.
dc.language.isoeng
dc.subjectBiyoinformatik
dc.subjectTemel Bilimler
dc.subjectMühendislik ve Teknoloji
dc.subjectBilgisayar Bilimleri
dc.subjectBİLGİSAYAR BİLİMİ, İNTERDİSİPLİNER UYGULAMALAR
dc.subjectBilgisayar Bilimi
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMÜHENDİSLİK, BİYOMEDİKSEL
dc.subjectMühendislik
dc.subjectMATEMATİKSEL VE ​​BİLGİSAYAR BİYOLOJİSİ
dc.subjectBiyoloji ve Biyokimya
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectTIBBİ BİLİŞİM
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectBilgisayar Grafiği
dc.subjectBiyomedikal Mühendisliği
dc.subjectYaşam Bilimleri
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectTemel Tıp Bilimleri
dc.subjectBiyoistatistik ve Tıp Bilişimi
dc.subjectBiyokimya
dc.titlePhysiological quality assessment of stored whole blood by means of electrical measurements
dc.typeMakale
dc.relation.journalMEDICAL & BIOLOGICAL ENGINEERING & COMPUTING
dc.contributor.departmentBoğaziçi Üniversitesi , ,
dc.identifier.volume45
dc.identifier.issue7
dc.identifier.startpage653
dc.identifier.endpage660
dc.contributor.firstauthorID611927