A Cost-Effective Microwave Ion Source Test Stand
Date
2020Author
Sahin, Latife
Çetinkaya, Hakan
Algin, Emel
Turemen, Gorkem
Dogan, Umit
Metadata
Show full item recordAbstract
Turkish Accelerator Center (TAC) Proton Accelerator Facility (PAF) is a project proposal that aims to build a megawatt (MW) power proton accelerator in Turkey. The proton source of this project was chosen as a microwave discharge ion source due to its long life time, its high current, and its lower maintenance requirements when compared with other ion source types. A microwave discharge ion source test stand was built to gain experience for TAC PAF and for similar projects requiring high beam current in Turkey. A magnetron with 2.45-GHz frequency, 50-Hz repetition rate, and 150-W fixed power was used to create the hydrogen plasma. Two different electrode systems were experimented: the first design consists of 2-mm radius plasma electrode that extracts beam currents up to 0.75 mA and the second design consists of 4-mm radius plasma electrode that extracts beam currents up to 5.2 mA.
URI
http://hdl.handle.net/20.500.12627/5390https://ieeexplore.ieee.org/document/9069444
https://doi.org/10.1109/tps.2020.2986416
Collections
- Makale [92796]