Basit öğe kaydını göster

dc.contributor.authorBayraktar, BÜLENT
dc.contributor.authorOzerkan, Kemal Nuri
dc.contributor.authorYucesir, Ilker
dc.contributor.authorGoksu, Omer Can
dc.contributor.authorSahinkaya, Türker
dc.contributor.authorYildiz, Safinaz
dc.date.accessioned2021-03-03T18:22:12Z
dc.date.available2021-03-03T18:22:12Z
dc.identifier.citationOzerkan K. N. , Bayraktar B., Sahinkaya T., Goksu O. C. , Yucesir I., Yildiz S., "Comparison of the effectiveness of the traditional acupuncture point, St. 36 and Omura's St.36 point (true St. 36) needling on the isokinetic knee extension & flexion strength of young soccer players", ACUPUNCTURE & ELECTRO-THERAPEUTICS RESEARCH, cilt.32, ss.71-79, 2007
dc.identifier.issn0360-1293
dc.identifier.othervv_1032021
dc.identifier.otherav_4ea7ef33-5d31-4d45-9db5-dcf1b689744b
dc.identifier.urihttp://hdl.handle.net/20.500.12627/56169
dc.identifier.urihttps://doi.org/10.3727/036012907815844129
dc.description.abstractThe purpose of this study was to compare the effects of the Traditional acupuncture point ST.36 and 'Omura's ST.36 Point' ("True ST.36") needling on the isokinetic knee extension & flexion strength of young soccer players. The Bi-Digital O-Ring Test (B.D.O.R.T.) of Yoshiaki Omura, M.D.,Sc.D. was used to determine the "True ST.36". Young soccer players (N= 24) between 16-18 years of age (Mean = 16.92 +/- 0.65) were involved in the study. The extension & flexion strengths of dominant legs were measured with Cybex 350 Extremity System isokinetically. The testing velocity was 60'/sec, The peak torque value in Newton meters (Nm) was evaluated. Subjects were tested 3 times. Extension & Flexion I (EXTI, FLEX!) without acupuncture application, EXT2 & FLEX2 after application on the traditional acupuncture point, ST.36 and EXT3 & FLEX3 after application onto the 'Omura's New Foot-point'("True ST.36"). Before each test, subjects warmed up for 10 minutes by cycling on an isokinetic ergometer at 50 RPM, 75 Watts load followed by stretching exercises of lower extremity. Mean EXTI, EXT2, EXT3 values were 196,92 +/- 28,70; 210,00 +/- 23,00; 224,42 +/- 21,70 respectively, where FLEX1, FLEX2, FLEX3 were 140,88 +/- 22,45; 151,13 +/- 21,27; 161,00 +/- 22,23. Comparisons of EXTI-EXT2, EXTI-EXT3, EXT2-EXT3, FLEXIFLEX2, FLEX1-FLEX3, FLEX2-FLEX3 strength values showed all very high significance (P < 0,001) in favor of 1) Needling on relevant points and 2) Omura's ST.36 Point ("True ST.36"). We conclude that B.D.O.R.T. can help to determine new (True) Acupuncture points and, both points were effective for increasing the isokinetic knee extension & flexion strength of young soccer players very significantly where as Omura's ST.36 Point ("True ST.36") was more effective than Traditional Acupuncture point, ST.36.
dc.language.isoeng
dc.subjectSağlık Bilimleri
dc.subjectYaşam Bilimleri
dc.subjectTemel Bilimler
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectTıp
dc.subjectSinirbilim ve Davranış
dc.subjectNEUROSCIENCES
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectENTEGRE VE TAMAMLAYICI TIP
dc.titleComparison of the effectiveness of the traditional acupuncture point, St. 36 and Omura's St.36 point (true St. 36) needling on the isokinetic knee extension & flexion strength of young soccer players
dc.typeMakale
dc.relation.journalACUPUNCTURE & ELECTRO-THERAPEUTICS RESEARCH
dc.contributor.departmentİstanbul Üniversitesi , İstanbul Tıp Fakültesi , Temel Bilimler Bölümü
dc.identifier.volume32
dc.identifier.startpage71
dc.identifier.endpage79
dc.contributor.firstauthorID52479


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster