Basit öğe kaydını göster

dc.contributor.authorBeyzadeoglu, Tahsin
dc.contributor.authorPehlivanoglu, Tuna
dc.date.accessioned2021-03-04T07:38:37Z
dc.date.available2021-03-04T07:38:37Z
dc.date.issued2018
dc.identifier.citationBeyzadeoglu T., Pehlivanoglu T., "Biological Response Following Inlay Arthroplasty of the Knee: Cartilage Flow Over the Implant", CARTILAGE, cilt.9, sa.2, ss.156-160, 2018
dc.identifier.issn1947-6035
dc.identifier.otherav_5f3eaade-d073-4a9f-904e-3815aef524b9
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/66546
dc.identifier.urihttps://doi.org/10.1177/1947603517746723
dc.description.abstractObjective. Inlay arthroplasty (IA) has seen growing interest as a new primary arthroplasty intervention for patients that need to transition from biology to joint replacement. The purpose of this study was to investigate the biological response to this procedure. Design. Patients presenting with symptomatic mono-or bicompartmental arthrosis and varus malalignment underwent IA and concurrent medial open wedge high tibial osteotomy (HTO). A subset of patients required hardware removal and consented to second-look arthroscopy without biopsy allowing for assessment of IA components and compartment-specific findings related to implant fixation, cartilage flow, propagation of lesions, and opposing tibial surfaces. Results. In a series of 41 knees (35 patients) treated with combined IA and HTO (mean varus >7 degrees), 26 knees (23 patients, 18 male, 5 female) with a mean age of 52 years (range = 43-67) required HTO plate removal. Concurrent second look arthroscopy was performed at a mean of 14 months (range = 12-19) following the index procedure. On probing, all arthroplasty components showed solid fixation without gap formation. On the medial femoral condyle, 15 mm implants (n = 14) showed a peripheral cartilage flow of 12% (range = 5% to 25%), 20 mm implants (n = 12) of 9% (range 5% to 15%), and trochlear implants (n = 12) of 20% (range 10% to 40%). No progressive deterioration of the index defects or progression of tibial and retropatellar grades were seen. Conclusion. Joint surface reconstruction using IA showed stable fixation with peripheral cartilage coverage ranging from 9% to 20% and no further chondral damage on opposing surfaces. Future clinical effectiveness studies are required to support the positive biological integration.
dc.language.isoeng
dc.subjectOrtopedi ve Travmatoloji
dc.subjectCerrahi Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectORTOPEDİ
dc.titleBiological Response Following Inlay Arthroplasty of the Knee: Cartilage Flow Over the Implant
dc.typeMakale
dc.relation.journalCARTILAGE
dc.contributor.departmentHaliç Üniversitesi , ,
dc.identifier.volume9
dc.identifier.issue2
dc.identifier.startpage156
dc.identifier.endpage160
dc.contributor.firstauthorID252468


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster