Basit öğe kaydını göster

dc.contributor.authorWACTAWSKI-WENDE, Jean
dc.contributor.authorCekici, ALİ
dc.contributor.authorVan Dyke, Thomas E.
dc.contributor.authorBrowne, Richard W.
dc.contributor.authorKantarci, Alpdogan
dc.contributor.authorLamonte, Michael J.
dc.contributor.authorAndrews, Christopher A.
dc.contributor.authorHovey, Kathleen M.
dc.contributor.authorFalkner, Karen L.
dc.contributor.authorStephens, Danielle
dc.contributor.authorGENCO, Robert J.
dc.contributor.authorSCANNAPIECO, Frank A.
dc.date.accessioned2021-03-04T08:28:52Z
dc.date.available2021-03-04T08:28:52Z
dc.date.issued2013
dc.identifier.citationBrowne R. W. , Kantarci A., Lamonte M. J. , Andrews C. A. , Hovey K. M. , Falkner K. L. , Cekici A., Stephens D., GENCO R. J. , SCANNAPIECO F. A. , et al., "Performance of Multiplex Cytokine Assays in Serum and Saliva among Community-Dwelling Postmenopausal Women", PLOS ONE, cilt.8, sa.4, 2013
dc.identifier.issn1932-6203
dc.identifier.othervv_1032021
dc.identifier.otherav_63831dbd-cd43-424a-bb63-a6a0e9c2a758
dc.identifier.urihttp://hdl.handle.net/20.500.12627/69277
dc.identifier.urihttps://doi.org/10.1371/journal.pone.0059498
dc.description.abstractMultiplexing arrays increase the throughput and decrease sample requirements for studies employing multiple biomarkers. The goal of this project was to examine the performance of Multiplex arrays for measuring multiple protein biomarkers in saliva and serum. Specimens from the OsteoPerio ancillary study of the Women's Health Initiative Observational Study were used. Participants required the presence of at least 6 teeth and were excluded based on active cancer and certain bone issues but were not selected on any specific condition. Quality control (QC) samples were created from pooled serum and saliva. Twenty protein markers were measured on five multiplexing array panels. Sample pretreatment conditions were optimized for each panel. Recovery, lower limit of quantification (LLOQ) and imprecision were determined for each analyte. Statistical adjustment at the plate level was used to reduce imprecision estimates and increase the number of usable observations. Sample pre-treatment improved recovery estimates for many analytes. The LLOQ for each analyte agreed with manufacturer specifications except for MMP-1 and MMP-2 which were significantly higher than reported. Following batch adjustment, 17 of 20 biomarkers in serum and 9 of 20 biomarkers in saliva demonstrated acceptable precision, defined as <20% coefficient of variation (<25% at LLOQ). The percentage of cohort samples having levels within the reportable range for each analyte varied from 10% to 100%. The ratio of levels in saliva to serum varied from 1:100 to 28:1. Correlations between saliva and serum were of moderate positive magnitude and significant for CRP, MMP-2, insulin, adiponectin, GM-CSF and IL-5. Multiplex arrays exhibit high levels of analytical imprecision, particularly at the batch level. Careful sample pre-treatment can enhance recovery and reduce imprecision. Following statistical adjustments to reduce batch effects, we identified biomarkers that are of acceptable quality in serum and to a lesser degree in saliva using Multiplex arrays.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectÇOK DİSİPLİNLİ BİLİMLER
dc.subjectDoğa Bilimleri Genel
dc.subjectTemel Bilimler (SCI)
dc.titlePerformance of Multiplex Cytokine Assays in Serum and Saliva among Community-Dwelling Postmenopausal Women
dc.typeMakale
dc.relation.journalPLOS ONE
dc.contributor.departmentState University of New York (SUNY) System , ,
dc.identifier.volume8
dc.identifier.issue4
dc.contributor.firstauthorID75492


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster