dc.identifier.citationOncu-Davas S., Alhan C., "Probabilistic behavior of semi-active isolated buildings under pulse-like earthquakes", SMART STRUCTURES AND SYSTEMS, cilt.23, sa.3, ss.227-242, 2019
dc.identifier.issn1738-1584
dc.identifier.otherav_6516f50b-8e67-48b9-9128-e379745b0768
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/70307
dc.identifier.urihttps://doi.org/10.12989/sss.2019.23.3.227
dc.description.abstractSeismic isolation systems employ structural control that protect both buildings and vibration-sensitive contents from destructive effects of earthquakes. Structural control is divided into three main groups: passive, active, and semi-active. Among them, semi-active isolation systems, which can reduce floor displacements and accelerations concurrently, has gained importance in recent years since they don't require large power or pose stability problems like active ones. However, their seismic performance may vary depending on the variations that may be observed in the mechanical properties of semi-active devices and/or seismic isolators. Uncertainties relating to isolators can arise from variations in geometry, boundary conditions, material behavior, or temperature, or aging whereas those relating to semi-active control devices can be due to thermal changes, inefficiencies in calibrations, manufacturing errors, etc. For a more realistic evaluation of the seismic behavior of semi-active isolated buildings, such uncertainties must be taken into account. Here, the probabilistic behavior of semi-active isolated buildings under historical pulse-like near-fault earthquakes is evaluated in terms of their performance in preserving structural integrity and protecting vibration-sensitive contents considering aforementioned uncertainties via Monte-Carlo simulations of 3-story and 9-story semi-active isolated benchmark buildings. The results are presented in the form of fragility curves and probability of failure profiles.
dc.language.isoeng
dc.subjectTarım Alet ve Makineleri
dc.subjectİnşaat Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectTarımsal Bilimler
dc.subjectTarım Makineleri
dc.subjectZiraat
dc.subjectALETLER & GÖSTERİM
dc.subjectMÜHENDİSLİK, MEKANİK
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, SİVİL
dc.titleProbabilistic behavior of semi-active isolated buildings under pulse-like earthquakes
dc.typeMakale
dc.relation.journalSMART STRUCTURES AND SYSTEMS
dc.contributor.departmentİstanbul Üniversitesi , Mühendislik Fakültesi , İnşaat Mühendisliği Bölümü
dc.identifier.volume23
dc.identifier.issue3
dc.identifier.startpage227
dc.identifier.endpage242
dc.contributor.firstauthorID262801