dc.description.abstractThis study reviews and compares the techniques such as LIMCA, PoDFA, Prefil, LIAS and RPT that are used to quantify defects in liquid aluminium alloys. in general, it is found that most of the current techniques are not fully satisfactory. Only the Reduced Pressure Test (RPT) appears to give reliable results of the number and size of bifilms (and sometimes, but not infallibly, an indication of hydrogen content). The density (or Density index) is valuable, but requires the supplement of additional quantification from the number and size of bifilms, which are recommended as additional major quality indicators. The use of a new Melt Quality chart is described.
dc.language.isoeng
dc.subjectMühendislik ve Teknoloji
dc.subjectMALZEME BİLİMİ, KARAKTERİZASYON VE TEST
dc.subjectMetalurji ve Malzeme Mühendisliği
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMalzeme Bilimi
dc.subjectMETALURJİ VE METALURJİ MÜHENDİSLİĞİ
dc.titleA comparison of methods used to assess aluminium melt quality
dc.typeBildiri
dc.contributor.department, ,
dc.contributor.firstauthorID133085


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster