Show simple item record

dc.contributor.authorÇENE, Erhan
dc.contributor.authorErdem, Mehmet Ali
dc.contributor.authorKose, Taha Emre
dc.contributor.authorAya, Serhan Aydjn
dc.contributor.authorCankaya, Abdulkadir Burak
dc.contributor.authorKOSE, Onur Dincer
dc.contributor.authorKaratasli, Burcin
dc.contributor.authorDEMIRCAN, Sabit
dc.date.accessioned2021-03-04T09:00:24Z
dc.date.available2021-03-04T09:00:24Z
dc.identifier.citationKOSE O. D. , Karatasli B., DEMIRCAN S., Kose T. E. , ÇENE E., Aya S. A. , Erdem M. A. , Cankaya A. B. , "In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening", BIOMED RESEARCH INTERNATIONAL, 2017
dc.identifier.issn2314-6133
dc.identifier.othervv_1032021
dc.identifier.otherav_6638a749-3080-4411-b683-55a9ad690035
dc.identifier.urihttp://hdl.handle.net/20.500.12627/70990
dc.identifier.urihttps://doi.org/10.1155/2017/7376261
dc.description.abstractPreload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield themanufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload.
dc.language.isoeng
dc.subjectSağlık Bilimleri
dc.subjectDahili Tıp Bilimleri
dc.subjectTıbbi Ekoloji ve Hidroklimatoloji
dc.subjectYaşam Bilimleri
dc.subjectBiyoteknoloji
dc.subjectTemel Bilimler
dc.subjectKlinik Tıp (MED)
dc.subjectTıp
dc.subjectKlinik Tıp
dc.subjectTIP, ARAŞTIRMA VE DENEYSEL
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectMikrobiyoloji
dc.subjectBİYOTEKNOLOJİ VE UYGULAMALI MİKROBİYOLOJİ
dc.titleIn Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
dc.typeMakale
dc.relation.journalBIOMED RESEARCH INTERNATIONAL
dc.contributor.department, ,
dc.contributor.firstauthorID75436


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record