dc.contributor.author | Yıldız, Esra | |
dc.contributor.author | Sancakli, Hande | |
dc.contributor.author | Erdemir, Ugur | |
dc.date.accessioned | 2021-03-04T09:01:07Z | |
dc.date.available | 2021-03-04T09:01:07Z | |
dc.date.issued | 2011 | |
dc.identifier.citation | Sancakli H., Erdemir U., Yıldız E., "Effects of Er:YAG Laser and Air Abrasion on the Microleakage of a Resin-Based Fissure Sealant Material", PHOTOMEDICINE AND LASER SURGERY, cilt.29, sa.7, ss.485-492, 2011 | |
dc.identifier.issn | 1549-5418 | |
dc.identifier.other | av_6646951d-d885-4578-9e7b-d312e082e68c | |
dc.identifier.other | vv_1032021 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/71035 | |
dc.identifier.uri | https://doi.org/10.1089/pho.2010.2889 | |
dc.description.abstract | Objective: The aim of the present study was to evaluate the effects of different surface pre-treatment techniques on the microleakage of a resin-based fissure sealant material. Methods:Thirty-five molars were divided into the following seven groups based on the surface pre-treatment technique used:(a) Erbium:Yttrium Aluminium Garnet (Er:YAG) laser (7 W); (b) Er:YAG laser (7 W)+acid etching (with 37% phosphoric acid); (c) Er:YAG laser (5.5 W); (d) Er:YAG laser (5.5 W)+acid etching; (e) air abrasion+acid etching; (f) air abrasion; and (g) conventional acid etching. The sealant was placed according to the manufacturers' instructions and light-cured for 20 sec. The sealed teeth were thermocycled for 10,000 cycles (58-55 degrees C), then immersed in 5% methylene blue for 24 h and sectioned mesiodistally. Each section was analyzed and photographed using a light microscope. Microleakage was assessed quantitatively by the degree of dye penetration and also qualitatively, scored on a three-point rating scale. Data were analyzed by one-way analysis of variance (ANOVA) and the Kruskal-Wallis test. The level of significance was set at p < 0.05. Results:Regardless of the fissure morphology and penetration depth, enamel surfaces conditioned with Er:YAG laser irradiation exhibited significantly higher microleakage than those conditioned with air abrasion followed by acid etching, and those conditioned with conventional acid etching (p < 0.05). Air abrasion followed by acid etching, as well as conventional acid etching, provided a sufficient seal, whereas laser irradiation alone or in combination with acid etching exhibited higher microleakage than did the other groups. Conclusions: Conventional acid etching remains the most effective and the simplest technique. | |
dc.language.iso | eng | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Sağlık Bilimleri | |
dc.subject | CERRAHİ | |
dc.subject | Klinik Tıp | |
dc.subject | Tıp | |
dc.subject | Cerrahi Tıp Bilimleri | |
dc.title | Effects of Er:YAG Laser and Air Abrasion on the Microleakage of a Resin-Based Fissure Sealant Material | |
dc.type | Makale | |
dc.relation.journal | PHOTOMEDICINE AND LASER SURGERY | |
dc.contributor.department | İstanbul Teknik Üniversitesi , , | |
dc.identifier.volume | 29 | |
dc.identifier.issue | 7 | |
dc.identifier.startpage | 485 | |
dc.identifier.endpage | 492 | |
dc.contributor.firstauthorID | 72277 | |