Basit öğe kaydını göster

dc.contributor.authorBilge, Hatice Bilge
dc.contributor.authorKoca, A
dc.contributor.authorDemir, Bayram
dc.contributor.authorKaracam, S
dc.contributor.authorGunhan, B
dc.contributor.authorDincbas, FO
dc.date.accessioned2021-03-04T09:08:33Z
dc.date.available2021-03-04T09:08:33Z
dc.date.issued2005
dc.identifier.citationDemir B., Bilge H. B. , Dincbas F., Koca A., Karacam S., Gunhan B., "The effect of pull back technique on dose distribution in the junction region for Sr-90/Y-90 intravascular brachytherapy sources", RADIATION MEASUREMENTS, cilt.39, sa.1, ss.29-32, 2005
dc.identifier.issn1350-4487
dc.identifier.othervv_1032021
dc.identifier.otherav_66da4abb-5421-400f-914b-f4ee2a954706
dc.identifier.urihttp://hdl.handle.net/20.500.12627/71401
dc.identifier.urihttps://doi.org/10.1016/j.radmeas.2004.06.010
dc.description.abstractThe aim of this work is to investigate the effect of pull back technique on dose distribution in the junction region for intravascular brachytherapy (IVBT) with beta source train. In this purpose, the five positions which were created with 0 cm gap, 2.5, 5 mm gap and 2.5, 5 mm overlap between active seeds were studied. The measurement for IVBT beta source train (Novoste Beta Cath) with 40 mm active source length were performed using radiochromic film dosimetry. Radiochromic film measurements were performed using a specially manufactured phantom, which was made of a white polystyrene material in our department. Radiochromic films were calibrated using Co-60 beams with 50, 100, 150, 200 Gy doses at 5 cm depth within solid water phantom in the same day. In the presence of a 2.5 mm (1 seed) and 5 mm (2 seed) gap, the dose in the middle of junction region can be decreased to 44% and 23%, respectively. On the other hand, in the presence of a 2.5 mm (1 seed) and 5 mm (2 seed) overlap, the dose can be increased as to much as 62% and 74%, respectively. In an IVBT application using pull back technique, the best dose distribution in the junction region was obtained with a perfect end-to-end match and our results show that significant underdose or overdose regions in the junction can occur in the presence of gap or overlap. Therefore, to create a perfect end-to-end match in an IVBT application using pull back technique, all movements of balloon should be recorded and the sources have been carefully placed to irradiate the injured vessel part with sufficient radiation doses. (C) 2004 Elsevier Ltd. All rights reserved.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectNükleer Fizik
dc.subjectTemel Bilimler (SCI)
dc.subjectFizik
dc.subjectNÜKLEAR BİLİMİ VE TEKNOLOJİSİ
dc.titleThe effect of pull back technique on dose distribution in the junction region for Sr-90/Y-90 intravascular brachytherapy sources
dc.typeMakale
dc.relation.journalRADIATION MEASUREMENTS
dc.contributor.department, ,
dc.identifier.volume39
dc.identifier.issue1
dc.identifier.startpage29
dc.identifier.endpage32
dc.contributor.firstauthorID173851


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster