dc.contributor.author | Aydar, Sevda | |
dc.contributor.author | Avan, Asiye Aslihan | |
dc.contributor.author | Filik, Hayati | |
dc.contributor.author | Cetintas, Gamze | |
dc.date.accessioned | 2021-03-04T09:38:11Z | |
dc.date.available | 2021-03-04T09:38:11Z | |
dc.date.issued | 2014 | |
dc.identifier.citation | Filik H., Avan A. A. , Aydar S., Cetintas G., "Determination of Acetaminophen in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Poly(Caffeic acid)", INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, cilt.9, sa.1, ss.148-160, 2014 | |
dc.identifier.issn | 1452-3981 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.other | av_691fa4f1-82e5-4417-bf3e-a970f76c755a | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/72856 | |
dc.description.abstract | A stable electroactive thin film of poly(caffeic acid) was deposited on the surface of a glassy carbon electrode by potentiostatic technique in an aqueous solution containing caffeic acid. The electrochemical behaviors of acetaminophen on poly(caffeic acid) modified glassy carbon electrodes (poly(CA)-GCEs) were investigated by cyclic voltammetry and square-wave voltammetry (SWV). The results obtained that the poly(CA)-modified electrode was exhibited excellent electrochemical activity on the oxidation of acetaminophen. The calibration curve for APAP was shown two linear segments: the first linear segment increases from 0.2 to 1.0 and second linear segment increases up to 10 mu M. Using the first range of this calibration plot, a detection limit of 0.026 mu M is obtained for acetaminophen using square wave voltammetry. The poly(CA) electrode is selective not only for the detection of acetaminophen in the presence of ascorbic acid, dopamine, p-aminophenol and uric acid but also selective for the simultaneous determination of these four species present in a mixture. Finally, the proposed method was successfully applied to analysis of acetaminophen in pharmaceutical tablets. | |
dc.language.iso | eng | |
dc.subject | Fizikokimya | |
dc.subject | Elektrokimya | |
dc.subject | Temel Bilimler | |
dc.subject | Temel Bilimler (SCI) | |
dc.subject | Kimya | |
dc.subject | ELEKTROKİMYA | |
dc.title | Determination of Acetaminophen in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Poly(Caffeic acid) | |
dc.type | Makale | |
dc.relation.journal | INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | |
dc.contributor.department | İstanbul Üniversitesi , , | |
dc.identifier.volume | 9 | |
dc.identifier.issue | 1 | |
dc.identifier.startpage | 148 | |
dc.identifier.endpage | 160 | |
dc.contributor.firstauthorID | 15566 | |