Show simple item record

dc.contributor.authorTEKÇE, NESLİHAN
dc.contributor.authorTuncer, Safa
dc.contributor.authorDemirci, Mustafa
dc.contributor.authorPala, Kansad
dc.date.accessioned2021-03-04T11:11:55Z
dc.date.available2021-03-04T11:11:55Z
dc.date.issued2016
dc.identifier.citationTEKÇE N., Pala K., Demirci M., Tuncer S., "Changes in surface characteristics of two different resin composites after 1 year water storage: An SEM and AFM study", SCANNING, cilt.38, sa.6, ss.694-700, 2016
dc.identifier.issn0161-0457
dc.identifier.otherav_711299ad-d19d-468a-b67e-fd506d5be70b
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/77911
dc.identifier.urihttps://doi.org/10.1002/sca.21317
dc.description.abstractTo evaluate changes in surface characteristics of two different resin composites after 1 year of water storage using a profilometer, Vickers hardness, scanning electron microscopy (SEM), and atomic force microscopy (AFM). A total of 46 composite disk specimens (10mm in diameter and 2mm thick) were fabricated using Clearfil Majesty Esthetic and Clearfil Majesty Posterior (Kuraray Medical Co, Tokyo, Japan). Ten specimens from each composite were used for surface roughness and microhardness tests (n=10). For each composite, scanning electron microscope (SEM, n=2) and atomic force microscope (AFM, n=1) images were obtained after 24h and 1 year of water storage. The data were analyzed using two-way analysis of variance and a post-hoc Bonferroni test. Microhardness values of Clearfil Majesty Esthetic decreased significantly (78.15-63.74, p=0.015) and surface roughness values did not change after 1 year of water storage (0.36-0.39, p=0.464). Clearfil Majesty Posterior microhardness values were quite stable (138.74-137.25, p=0.784), and surface roughness values increased significantly (0.39-0.48, p=0.028) over 1 year. One year of water storage caused microhardness values for Clearfil Majesty Esthetic to decrease and the surface roughness of Clearfil Majesty Posterior increased. AFM and SEM images demonstrated surface detoration of the materials after 1 year and ensured similar results with the quantitative test methods. SCANNING 38:694-700, 2016. (c) 2016 Wiley Periodicals, Inc.
dc.language.isoeng
dc.subjectMühendislik ve Teknoloji
dc.subjectYaşam Bilimleri
dc.subjectTemel Bilimler
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectMikrobiyoloji
dc.subjectMİKROSKOPİ
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectALETLER & GÖSTERİM
dc.titleChanges in surface characteristics of two different resin composites after 1 year water storage: An SEM and AFM study
dc.typeMakale
dc.relation.journalSCANNING
dc.contributor.departmentErciyes Üniversitesi , ,
dc.identifier.volume38
dc.identifier.issue6
dc.identifier.startpage694
dc.identifier.endpage700
dc.contributor.firstauthorID47846


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record