Show simple item record

dc.contributor.authorIlkova, H
dc.contributor.authorBagriacik, N
dc.contributor.authorBeyhan, S
dc.contributor.authorOzyazar, M
dc.contributor.authorGorpe, U
dc.contributor.authorDamci, T
dc.contributor.authorOsar, Z
dc.date.accessioned2021-03-04T11:31:37Z
dc.date.available2021-03-04T11:31:37Z
dc.date.issued1999
dc.identifier.citationDamci T., Osar Z., Beyhan S., Ilkova H., Ozyazar M., Gorpe U., Bagriacik N., "Does instantaneous blood glucose affect vibration perception threshold measurement using biothesiometer?", DIABETES RESEARCH AND CLINICAL PRACTICE, cilt.46, sa.1, ss.19-22, 1999
dc.identifier.issn0168-8227
dc.identifier.otherav_72be73a8-3341-4785-aa16-2827df58f0de
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/78976
dc.identifier.urihttps://doi.org/10.1016/s0168-8227(99)00064-9
dc.description.abstractDiabetic neuropathy is a common and troublesome complication of diabetes mellitus. Vibration sensation is a measure of large fiber nerve conduction, which is very commonly affected in diabetes. The present study addresses the question of whether vibration perception threshold (VPT) measurement using a biothesiometer is reproducible under different levels of blood glucose at different hours of the day. Seventy-five diabetic patients, 31 insulin-dependent diabetes mellitus and 44 non-insulin-dependent diabetes mellitus, with mean age 50.33 +/- 14.22 years (21-70 years) and diabetes duration of 14.3 +/- 10.6 years (1-60 years) were included in the study. Forty-one patients were male and 34 were female. In conclusion, VPT was found to be reproducible under different blood glucose levels at different hours of the day, which is affected only by the height of the patient. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
dc.language.isoeng
dc.subjectDahili Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectİç Hastalıkları
dc.subjectEndokrinoloji ve Metabolizma Hastalıkları
dc.subjectENDOKRİNOLOJİ VE METABOLİZMA
dc.titleDoes instantaneous blood glucose affect vibration perception threshold measurement using biothesiometer?
dc.typeMakale
dc.relation.journalDIABETES RESEARCH AND CLINICAL PRACTICE
dc.contributor.department, ,
dc.identifier.volume46
dc.identifier.issue1
dc.identifier.startpage19
dc.identifier.endpage22
dc.contributor.firstauthorID124034


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record