dc.identifier.citationAkalan N. E. , Ozkan M., Temelli Y., "Three-dimensional knee model: Constrained by isometric ligament bundles and experimentally obtained tibio-femoral contacts", JOURNAL OF BIOMECHANICS, cilt.41, sa.4, ss.890-896, 2008
dc.identifier.issn0021-9290
dc.identifier.otherav_7435e79f-eca1-4e05-a3f0-1d35d2d48918
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/79867
dc.identifier.urihttps://doi.org/10.1016/j.jbiomech.2007.10.021
dc.description.abstractThe purpose of this study is to investigate the effect of anterior portion of anterior cruciate ligament, posterior cruciate ligament, anterior and deep portions of medial collateral ligament and the tibio-femoral articular contacts on passive knee motion. A well-accepted reference model for a normal tibio-femoral joint is reconstructed from the literature. The proposed three-dimensional dynamic tibio-femoral model includes the isometric fascicles, ligament bundles and irregularly shaped medial-lateral contact surfaces. With the approach we aim to analyze bone shape and ligament related abnormalities of knee kinematics. The rotations, translations and the contact forces during passive knee flexion were compared against a reference model and the results were found in close accordance. This study demonstrated that isometric ligament bundles play an important role in understanding the femur shape from contact points on tibia. Femoral condyles are not necessarily spherical. The surgical treatments should consider both ligament bundle lengths and contact surface geometries to achieve a problem free knee kinematics after a knee surgery. (C) 2007 Elsevier Ltd. All rights reserved.
dc.language.isoeng
dc.subjectTemel Tıp Bilimleri
dc.subjectBiyofizik
dc.subjectBiyokimya
dc.subjectBiyomedikal Mühendisliği
dc.subjectYaşam Bilimleri
dc.subjectTemel Bilimler
dc.subjectMühendislik ve Teknoloji
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, BİYOMEDİKSEL
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectBiyoloji ve Biyokimya
dc.subjectBİYOFİZİK
dc.titleThree-dimensional knee model: Constrained by isometric ligament bundles and experimentally obtained tibio-femoral contacts
dc.typeMakale
dc.relation.journalJOURNAL OF BIOMECHANICS
dc.contributor.departmentBoğaziçi Üniversitesi , ,
dc.identifier.volume41
dc.identifier.issue4
dc.identifier.startpage890
dc.identifier.endpage896
dc.contributor.firstauthorID69897


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record