dc.contributor.author | Ayaz, M | |
dc.contributor.author | Uslu, I | |
dc.contributor.author | Sonmezoglu, K | |
dc.contributor.author | Kalender, B | |
dc.contributor.author | Sayman, HB | |
dc.contributor.author | Kabasakal, L | |
dc.contributor.author | Halac, M | |
dc.contributor.author | Yapar, AF | |
dc.contributor.author | Alkan, E | |
dc.contributor.author | Kanmaz, B | |
dc.contributor.author | Onsel, C | |
dc.date.accessioned | 2021-03-04T12:31:09Z | |
dc.date.available | 2021-03-04T12:31:09Z | |
dc.date.issued | 1999 | |
dc.identifier.citation | Kabasakal L., Halac M., Yapar A., Alkan E., Kanmaz B., Onsel C., Sonmezoglu K., Ayaz M., Kalender B., Sayman H., et al., "Prospective validation of single plasma sample Tc-99m-ethylenedicysteine clearance in adults", JOURNAL OF NUCLEAR MEDICINE, cilt.40, sa.3, ss.429-431, 1999 | |
dc.identifier.issn | 0161-5505 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.other | av_77b290aa-ba11-439a-abbd-62588f1e1608 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/82158 | |
dc.description.abstract | Tc-99m-L,L-ethylene, L, dicysteine (EC) clearance shows strong correlation with orthoiodohippurate clearance, and it is possible to estimate effective renal plasma flow from Tc-99m-EC clearance. In routine clinical studies, it is practical to use the one or two plasma sample method instead of multiple plasma samples for clearance determination. A single-sample technique was developed for Tc-99m-EC, and a regression formula was generated. A prospective study tested the validity of this regression formula. Methods: The study population was composed of 26 patients with a wide range of renal function. Multiple plasma sample Tc-99m-EC clearances were calculated from all patients using the open two-compartment model, Single plasma sample clearances were also determined from the 54-min plasma sample using the regression formula published previously. Results: The multiple-sample plasma clearance of Tc-99m-EC ranged from 46 to 668 mL/min with a mean of 300.76 +/- 150.73 mL/min. The clearances obtained from the 54-min plasma sample ranged from 49 to 699 mL/min, with a mean of 297.39 +/- 152.23 mL/min, There was an excellent correlation between the clearances obtained by the two techniques (r = 0.99, slope = 0.9911). The standard error of estimation was found to be 25.9 mL/min, Conclusion: This study suggests that Tc-99m-EC clearance can be estimated from 54-min plasma samples with an acceptable error of estimation for most routine clinical studies. | |
dc.language.iso | eng | |
dc.subject | Tıp | |
dc.subject | Nükleer Tıp | |
dc.subject | Sağlık Bilimleri | |
dc.subject | Dahili Tıp Bilimleri | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Klinik Tıp | |
dc.subject | RADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME | |
dc.title | Prospective validation of single plasma sample Tc-99m-ethylenedicysteine clearance in adults | |
dc.type | Makale | |
dc.relation.journal | JOURNAL OF NUCLEAR MEDICINE | |
dc.contributor.department | , , | |
dc.identifier.volume | 40 | |
dc.identifier.issue | 3 | |
dc.identifier.startpage | 429 | |
dc.identifier.endpage | 431 | |
dc.contributor.firstauthorID | 122883 | |