Basit öğe kaydını göster

dc.contributor.authorAyaz, M
dc.contributor.authorUslu, I
dc.contributor.authorSonmezoglu, K
dc.contributor.authorKalender, B
dc.contributor.authorSayman, HB
dc.contributor.authorKabasakal, L
dc.contributor.authorHalac, M
dc.contributor.authorYapar, AF
dc.contributor.authorAlkan, E
dc.contributor.authorKanmaz, B
dc.contributor.authorOnsel, C
dc.date.accessioned2021-03-04T12:31:09Z
dc.date.available2021-03-04T12:31:09Z
dc.date.issued1999
dc.identifier.citationKabasakal L., Halac M., Yapar A., Alkan E., Kanmaz B., Onsel C., Sonmezoglu K., Ayaz M., Kalender B., Sayman H., et al., "Prospective validation of single plasma sample Tc-99m-ethylenedicysteine clearance in adults", JOURNAL OF NUCLEAR MEDICINE, cilt.40, sa.3, ss.429-431, 1999
dc.identifier.issn0161-5505
dc.identifier.othervv_1032021
dc.identifier.otherav_77b290aa-ba11-439a-abbd-62588f1e1608
dc.identifier.urihttp://hdl.handle.net/20.500.12627/82158
dc.description.abstractTc-99m-L,L-ethylene, L, dicysteine (EC) clearance shows strong correlation with orthoiodohippurate clearance, and it is possible to estimate effective renal plasma flow from Tc-99m-EC clearance. In routine clinical studies, it is practical to use the one or two plasma sample method instead of multiple plasma samples for clearance determination. A single-sample technique was developed for Tc-99m-EC, and a regression formula was generated. A prospective study tested the validity of this regression formula. Methods: The study population was composed of 26 patients with a wide range of renal function. Multiple plasma sample Tc-99m-EC clearances were calculated from all patients using the open two-compartment model, Single plasma sample clearances were also determined from the 54-min plasma sample using the regression formula published previously. Results: The multiple-sample plasma clearance of Tc-99m-EC ranged from 46 to 668 mL/min with a mean of 300.76 +/- 150.73 mL/min. The clearances obtained from the 54-min plasma sample ranged from 49 to 699 mL/min, with a mean of 297.39 +/- 152.23 mL/min, There was an excellent correlation between the clearances obtained by the two techniques (r = 0.99, slope = 0.9911). The standard error of estimation was found to be 25.9 mL/min, Conclusion: This study suggests that Tc-99m-EC clearance can be estimated from 54-min plasma samples with an acceptable error of estimation for most routine clinical studies.
dc.language.isoeng
dc.subjectTıp
dc.subjectNükleer Tıp
dc.subjectSağlık Bilimleri
dc.subjectDahili Tıp Bilimleri
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.titleProspective validation of single plasma sample Tc-99m-ethylenedicysteine clearance in adults
dc.typeMakale
dc.relation.journalJOURNAL OF NUCLEAR MEDICINE
dc.contributor.department, ,
dc.identifier.volume40
dc.identifier.issue3
dc.identifier.startpage429
dc.identifier.endpage431
dc.contributor.firstauthorID122883


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster