dc.contributor.author | Ak, Serap | |
dc.contributor.author | Bilir, S | |
dc.contributor.author | Karaali, S | |
dc.contributor.author | Karatas, Y | |
dc.date.accessioned | 2021-03-04T14:32:20Z | |
dc.date.available | 2021-03-04T14:32:20Z | |
dc.date.issued | 2003 | |
dc.identifier.citation | Karaali S., Bilir S., Karatas Y., Ak S., "New metallicity calibration down to [Fe/H]=-2.75 dex", PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF AUSTRALIA, cilt.20, sa.2, ss.165-172, 2003 | |
dc.identifier.issn | 1323-3580 | |
dc.identifier.other | av_8217b6ee-d029-4711-9468-e7d544a6ce04 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/88603 | |
dc.identifier.uri | https://doi.org/10.1071/as02028 | |
dc.description.abstract | We have taken 88 dwarfs, covering the colour-index interval 0.37 less than or equal to (B-V)(0) less than or equal to 1.07 mag, with metallicities - 2.70 less than or equal to [Fe/H] less than or equal to + 0.26 dex, from three different sources for new metallicity calibration. The catalogue of Cayrel de Strobel et al. ( 2001), which includes 65% of the stars in our sample, supplies detailed information on abundances for stars with determination based on high-resolution spectroscopy. In constructing the new calibration we have used as 'corner stones' 77 stars which supply at least one of the following conditions: (i) the parallax is larger than 10 mas ( distance relative to the Sun less than 100 pc) and the galactic latitude is absolutely higher than 30degrees; (ii) the parallax is rather large, if the galactic latitude is absolutely low and vice versa. Contrary to previous investigations, a third-degree polynomial is fitted for the new calibration: [Fe/H]= 0.10 - 2.76delta - 24.04delta(2) + 30.00delta(3). The coefficients were evaluated by the least-squares method, without regard to the metallicity of Hyades. However, the constant term is in the range of metallicity determined for this cluster, i.e. 0.08 less than or equal to [Fe/ H] less than or equal to 0.11 dex. The mean deviation and the mean error in our work are equal to those of Carney (1979), for [Fe/H] greater than or equal to - 1.75 dex where Carney's calibration is valid. | |
dc.language.iso | eng | |
dc.subject | Astronomi ve Astrofizik | |
dc.subject | ASTRONOMİ VE ASTROFİZİK | |
dc.subject | Uzay bilimi | |
dc.subject | Temel Bilimler (SCI) | |
dc.subject | Fizik | |
dc.subject | Temel Bilimler | |
dc.title | New metallicity calibration down to [Fe/H]=-2.75 dex | |
dc.type | Makale | |
dc.relation.journal | PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF AUSTRALIA | |
dc.contributor.department | , , | |
dc.identifier.volume | 20 | |
dc.identifier.issue | 2 | |
dc.identifier.startpage | 165 | |
dc.identifier.endpage | 172 | |
dc.contributor.firstauthorID | 166884 | |