Basit öğe kaydını göster

dc.contributor.authorWolf, Y.
dc.contributor.authorNuman, F.
dc.contributor.authorFitridge, R.
dc.contributor.authorHayes, P.
dc.contributor.authorSilveira, P. G.
dc.contributor.authorBoeckler, D.
dc.contributor.authorRiambau, V.
dc.date.accessioned2021-03-04T15:05:53Z
dc.date.available2021-03-04T15:05:53Z
dc.date.issued2011
dc.identifier.citationBoeckler D., Riambau V., Fitridge R., Wolf Y., Hayes P., Silveira P. G. , Numan F., "Worldwide experience with the Endurant Stent-graft System: Review of the literature", JOURNAL OF CARDIOVASCULAR SURGERY, cilt.52, sa.5, ss.669-681, 2011
dc.identifier.issn0021-9509
dc.identifier.othervv_1032021
dc.identifier.otherav_84f415e5-4842-45c9-8968-0fa13c062a14
dc.identifier.urihttp://hdl.handle.net/20.500.12627/90428
dc.description.abstractThe Endurant Stent-graft System (Medtronic Vascular, Santa Rosa, CA, USA) is a next-generation device intended to expand the applicability of endovascular aortic repair (EVAR). To date, the Endurant has been evaluated in 9 short- and intermediate-term studies, several in patients presenting with challenging aneurysm anatomies. Consistently, the device in these studies has been shown to be safe and effective, with an excellent rate of deployment success and with very low rates of type I/III endoleaks and reinterventions. Single-center experience with the Endurant in high-risk patients with challenging anatomies, such as short kinked necks and calcified angulated iliac arteries, shows promising early results with no differences in mortality, morbidity, and reintervention rates compared to those of low-risk patients. But caution is warranted for application of the Endurant outside of the instructions for use. The Endurant StentGraft Natural Selection Global Postmarket Registry (ENGAGE) is a long-term 1266-patient 80-site worldwide prospective postmarket study initiated to augment the knowledge base (poolable and comparable) about EVAR in a real-world population implanted with the Endurant. Technical and clinical data for ENGAGE patients will be reported through the expected completion of 5-year follow-up for all ENGAGE registry patients in 2018. We discuss the evolving challenges for EVAR that the Endurant and other next-generation stent-grafts are designed to address and review outcomes published with the Endurant since the CE marking of the device in July 2008.
dc.language.isoeng
dc.subjectDahili Tıp Bilimleri
dc.subjectKardiyoloji
dc.subjectCerrahi Tıp Bilimleri
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectPERİFERAL VASKÜLER HASTALIĞI
dc.subjectCERRAHİ
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectCARDIAC ve CARDIOVASCULAR SİSTEMLER
dc.titleWorldwide experience with the Endurant Stent-graft System: Review of the literature
dc.typeMakale
dc.relation.journalJOURNAL OF CARDIOVASCULAR SURGERY
dc.contributor.departmentRuprecht Karls University Heidelberg , ,
dc.identifier.volume52
dc.identifier.issue5
dc.identifier.startpage669
dc.identifier.endpage681
dc.contributor.firstauthorID10722


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster