Basit öğe kaydını göster

dc.contributor.authorOzdamar, A
dc.contributor.authorAras, Cengiz
dc.contributor.authorUSTUNDAG, C
dc.contributor.authorOzkan, S
dc.contributor.authorTAMCELIK, Nevbahar
dc.date.accessioned2021-03-04T17:29:23Z
dc.date.available2021-03-04T17:29:23Z
dc.date.issued2001
dc.identifier.citationOzdamar A., Aras C., USTUNDAG C., TAMCELIK N., Ozkan S., "Scleral tunnel for the implantation of glaucoma seton devices", OPHTHALMIC SURGERY AND LASERS, cilt.32, sa.5, ss.432-435, 2001
dc.identifier.issn0022-023X
dc.identifier.othervv_1032021
dc.identifier.otherav_861ea8e8-4eaf-40d0-9e79-6689918ad86b
dc.identifier.urihttp://hdl.handle.net/20.500.12627/91146
dc.description.abstractThe technique described in this paper shows how to use a long scleral tunnel for the implantation of anterior tube parts of glaucoma drainage devices. It involves the creation of a scleral tunnel beginning 10 mm behind the limbus and extending to the anterior chamber. Anterior tube parts of Krupin eye valve with disk is inserted through the scleral tunnel to the anterior chamber. The disk part is secured to the episclera as used in the standard technique. We have used this technique in 6 eyes of 6 consecutive patients with refractory glaucoma. The placement of anterior tubes as part of glaucoma seton devices was done in all patients. While mean intraocular pressure (IOP) was 39.3 +/- 4.9 mm Hg (ranged from 29 to 56 mm, Hg) preoperatively, it was 16.6 +/- 5.3 mm Hg (ranging from 11 to 25 ram Hg) at the end of follow up. Mean follow-up time was 7.16 +/- 1.16 months (ranging from 6 to 9 months). After surgery conjunctival erosion or displacement of the anterior tube and dellen formation were not found in any eyes. The use of a long scleral tunnel for the implantation of anterior tube parts of glaucoma seton devices offers some advantages over standard implantation techniques.
dc.language.isoeng
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectCerrahi Tıp Bilimleri
dc.subjectGöz Hastalıkları ve Cerrahisi
dc.subjectOFTALMOLOJİ
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectCERRAHİ
dc.titleScleral tunnel for the implantation of glaucoma seton devices
dc.typeMakale
dc.relation.journalOPHTHALMIC SURGERY AND LASERS
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume32
dc.identifier.issue5
dc.identifier.startpage432
dc.identifier.endpage435
dc.contributor.firstauthorID53991


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster