Show simple item record

dc.contributor.authorTozun, R
dc.contributor.authorCantez, S
dc.contributor.authorDemirkol, MO
dc.contributor.authorAdalet, I
dc.contributor.authorUnal, SN
dc.date.accessioned2021-03-04T19:05:47Z
dc.date.available2021-03-04T19:05:47Z
dc.date.issued1997
dc.identifier.citationDemirkol M., Adalet I., Unal S., Tozun R., Cantez S., "Tc-99(m)-polyclonal IgG scintigraphy in the detection of infected hip and knee prostheses", NUCLEAR MEDICINE COMMUNICATIONS, cilt.18, ss.543-548, 1997
dc.identifier.issn0143-3636
dc.identifier.otherav_8e15ec11-610c-452d-a5ae-9a029d758e8b
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/96018
dc.identifier.urihttps://doi.org/10.1097/00006231-199706000-00008
dc.description.abstractWe investigated the usefulness of Tc-99(m)-polyclonal human IgG (Tc-99(m)-HIG) scintigraphy in the diagnosis of infected hip and knee prostheses. Twenty-nine scintigraphic studies were performed in 27 patients (17 females, 10 males) with a suspected prosthetic infection. As some patients had bilateral prostheses, a total of 35 prostheses were evaluated. There were 25 hip replacements and 10 knee prostheses. The images were analysed both visually and quantitatively. The scintigraphic results were compared with the culture results of surgical specimens and also with clinical follow-up after 3 months. Increased uptake was observed in 22 prostheses, of which 12 were true-positive and 10 were false-positive results. Staphylococci were the agents most commonly isolated. In all false-positive patients, aseptic inflammation was diagnosed. Based on quantitative analysis, no statistically significant difference was found between the true-positive and false-positive cases. For the prostheses as a whole, the sensitivity, specificity, positive predictive value and negative predictive value were 100%, 41%, 54% and 100% respectively. For the hip prostheses alone, these values were 100%, 53%, 57% and 100% respectively. Taking its high sensitivity and predictive value into consideration, Tc-99(m)-HIG scintigraphy can be used as a screening test to help eliminate prosthetic infection.
dc.language.isoeng
dc.subjectNükleer Tıp
dc.subjectDahili Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.titleTc-99(m)-polyclonal IgG scintigraphy in the detection of infected hip and knee prostheses
dc.typeMakale
dc.relation.journalNUCLEAR MEDICINE COMMUNICATIONS
dc.contributor.department, ,
dc.identifier.volume18
dc.identifier.issue6
dc.identifier.startpage543
dc.identifier.endpage548
dc.contributor.firstauthorID118837


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record