Show simple item record

dc.contributor.authorMIRSAL, Hasan
dc.contributor.authorOZDEMIR, Ali Acar
dc.contributor.authorAcikkol, Munevver
dc.contributor.authorAnilanmert, BERİL
dc.date.accessioned2021-03-04T19:29:43Z
dc.date.available2021-03-04T19:29:43Z
dc.date.issued2015
dc.identifier.citationAcikkol M., OZDEMIR A. A. , Anilanmert B., MIRSAL H., "A Highly Specific, Fully Validated Urinary Ethyl Glucuronide Analysis Using Solid Phase Extraction-Liquid Chromatography/Electrospray Ionization-Tandem Mass Spectrometry", JOURNAL OF AOAC INTERNATIONAL, cilt.98, ss.760-766, 2015
dc.identifier.issn1060-3271
dc.identifier.othervv_1032021
dc.identifier.otherav_900c3fff-a743-4689-8014-89194a666482
dc.identifier.urihttp://hdl.handle.net/20.500.12627/97244
dc.identifier.urihttps://doi.org/10.5740/jaoacint.14-094
dc.description.abstractA highly specific and selective analytical method using LC/MS/MS for the quantitative determination of ethyl glucuronide (EtG) in urine was developed and fully validated. Since the determination of EtG in urine may be possible days after the elimination of alcohol, it is an indication of alcohol use in alcohol treatment programs and antemortem and postmortem toxicological investigations. Propyl glucuronide (PrG), which increased the selectivity of the method, was used as an internal standard. The method was validated in terms of selectivity, linearity, LOD, LOQ, intraday and interday precision, and recovery. The analyte and PrG in the SPE cleaned up extract were separated on a 150 mm C-18 column in 3.3 min with high resolution. The rest of the peaks from the matrix were eluted in 9.0 min. The LOD was 90.8 ng/mL and the LOQ was calculated using the EURACHEM method as 185.0 ng/mL. The intraday and the intermediate precision of the method was calculated using analysis of variance and confirmed with calculation of HorRat values, which were found within acceptable limits. The method provided a reliable solution for monitoring patients under alcohol addiction treatment and was successfully applied to real samples.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectGıda Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectTarımsal Bilimler
dc.subjectZiraat
dc.subjectAnalitik Kimya
dc.subjectKİMYA, ANALİTİK
dc.subjectKimya
dc.subjectTemel Bilimler (SCI)
dc.subjectGIDA BİLİMİ VE TEKNOLOJİSİ
dc.subjectTarım Bilimleri
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.titleA Highly Specific, Fully Validated Urinary Ethyl Glucuronide Analysis Using Solid Phase Extraction-Liquid Chromatography/Electrospray Ionization-Tandem Mass Spectrometry
dc.typeMakale
dc.relation.journalJOURNAL OF AOAC INTERNATIONAL
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume98
dc.identifier.issue3
dc.identifier.startpage760
dc.identifier.endpage766
dc.contributor.firstauthorID100251


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record