Basit öğe kaydını göster

dc.contributor.authorKAYA, MUSTAFA SARP
dc.contributor.authorDurmus, Ali
dc.contributor.authorDurmus, Zehra
dc.contributor.authorBAKKAL, MELTEM
dc.date.accessioned2021-03-05T07:24:28Z
dc.date.available2021-03-05T07:24:28Z
dc.identifier.citationKAYA M. S. , BAKKAL M., Durmus A., Durmus Z., "Structural and mechanical properties of a giomer-based bulk fill restorative in different curing conditions", JOURNAL OF APPLIED ORAL SCIENCE, cilt.26, 2018
dc.identifier.issn1678-7757
dc.identifier.othervv_1032021
dc.identifier.otherav_93a8ef0e-da9f-4bac-abe7-6b3767fb9f7c
dc.identifier.urihttp://hdl.handle.net/20.500.12627/99496
dc.identifier.urihttps://doi.org/10.1590/1678-7757-2016-0662
dc.description.abstractObjective: The main goal of this study was to compare the polymerization degree of bulk-fill giomer resin cured with three different light-curing units (LCUs): a polywave third-generation (Valo); a monowave (DemiUltra: DU); and a second-generation LED (Optima 10: Opt) LCUs by using structural and mechanical properties. Material and methods: Giomer samples of 2 and 4 mm cured with three LCUs were employed in vitro analysis. The degree of curing (DC%) was determined with Fourier-Transform Infrared Spectroscopy (FTIR). Microstructural features were observed with scanning electron microscopy (SEM). Flexural strength (FS), compression strength (CS), elastic modulus and fracturing strain were determined for mechanical properties. Surface microhardness (SMH) values were also measured. One-way ANOVA, two-way analysis of variance and Tukey multiple comparison tests were used for statistically analyzing the FS and SMH. Results: DC% values were 58.2, 47.6, and 39.7 for the 2 mm samples cured with DU, Opt., and Valo LCUs, respectively. DC% values of the 4 mm samples were 50.4, 44.6, and 38.2 for DU, Opt, and Valo, respectively. SMH values were Valo, Opt<DU at top of the samples; Valo<DU, Opt at 2 mm, and DU, Valo<Opt at 4 mm depth. Giomer samples cured with Opt and DU exhibited higher FS values than Valo. CS values were similar but compressive modulus and fracturing strain (%) varied depending on the curing protocol. Conclusions: Based on the results, it can be concluded that curing device and protocol strongly affect crosslinking reactions and thus DC%, SMH, compressive modulus and strain at break values. Consequently, it can be deduced that curing protocol is possibly the most important parameter for microstructure formation of highly-filled composite restoratives because it may bring some structural defects and physical frailties on restorations due to lower degree of polymerization.
dc.language.isoeng
dc.subjectSağlık Bilimleri
dc.subjectDiş Hekimliği
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.titleStructural and mechanical properties of a giomer-based bulk fill restorative in different curing conditions
dc.typeMakale
dc.relation.journalJOURNAL OF APPLIED ORAL SCIENCE
dc.contributor.departmentBezmiâlem Vakıf Üniversitesi , Diş Hekimliği Fakültesi , Klinik Bilimler Bölümü
dc.identifier.volume26
dc.contributor.firstauthorID74849


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster